DSpace Repository

การเปรียบเทียบความส่องสว่างของการใช้หลอดไฟฟลูออดรสเซนต์กับหลอด LED ในอาคารศูนย์บรรณสารสนเทศ มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ

Show simple item record

dc.contributor.author ฐิตาภรณ์ เหลืองวิลัย
dc.contributor.author อุมารินทร์ พูลพานิชอุปถัมย์
dc.contributor.author สุรวิทย์ นันตะพร
dc.contributor.author จิตรภณ โรจน์กิรติการ
dc.contributor.author Titaporn Luangwilai
dc.contributor.author Umarin Poolpanichuppatam
dc.contributor.author Surawit Nantaporn
dc.contributor.author Jittapon Rojkiratikarn
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Public and Environmental Health th
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Public and Environmental Health
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Public and Environmental Health
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Public and Environmental Health
dc.date.accessioned 2023-03-12T15:35:01Z
dc.date.available 2023-03-12T15:35:01Z
dc.date.issued 2018
dc.identifier.uri https://has.hcu.ac.th/jspui/handle/123456789/1249
dc.description.abstract การวิจัยครั้งนี้ มีวัตถุประสงค์เพื่อศึกษาประสิทธิภาพแสงสว่าง อาคารศูนย์บรรณสารสารสนเทศ มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ ระหว่างหลอดฟลูออเรสเซนต์ T8 และหลอด LED กลุ่มตัวอย่างที่ใช้ในการวิจัย คือ จำนวนจุดตรวจวัดความเข้มแสงสว่าง อาคารบรรณสารสนเทศ จำนวนทั้งหมด 194 จุด โดยเป็นการเก็บจากทั้งหมดทุกชั้้นของอาคารบรรณสาร เครื่องมือที่ใช้ในการวิจัยในครั้งนี้ คือ เครื่องตรวจวัดความเข้มแสงสว่าง ที่ผ่านการปรับเทียบความถูกต้องของเครื่องมือโดยศูนย์ทดสอบและมาตรวิทยา กระทรวงวิทยาศาสตร์และเทคโนโลยี มีการนำเสนอผลการศึกษาความเข้มแสงสว่างโดยแสดงเป็นจำนวน ร้อยละ และวิเคราะห์ข้อมูลการเปรียบเทียบความเข้มแสงสว่างระหว่างหลอดฟลูออเรสเซนต์ T8 และหลอด LED โดยใช้สถิติ Indenpendent t-test ผลการศึกษาจากกลุ่มตัวอย่างทั้งหมด 194 จุด พบว่า ประสิทธิภาพของแสงสว่างจากหลอดฟลูออเรสเซนต์ T8 มีจุดที่มีความเข้มแสงสว่างผ่านตามเกณฑ์มาตรฐานคิดเป็นร้อยละ 27.84 มีค่าความเข้มแสงสว่างอยู่ในเกณฑ์ต่ำกว่ามาตรฐานตามกฎหมายกำหนด มีค่าเฉลี่ยอยู่ที่ 380.21 Lux เมื่อเปลี่ยนเป็นหลอดไฟ LED มีจุดที่มีความเข้มแสงสว่างผ่านตามเกณฑ์มาตรฐานคิดเป็นร้อยละ 85.57 มีค่าความเข้มแสงสว่างอยู่ในเกณฑ์สูงผ่านค่ามาตรฐานตามกฎหมายกำหนด มีค่าเฉลี่ยอยู่ที่ 593.98 Lux และจากการทดสอบด้วย Independent t-test แสดงให้เห็นว่าค่าเฉลี่ยของความเข้มแสงสว่างจากหลอด LED สูงกว่าค่าเฉลี่ยของความเข้มแสงสว่างจากหลอดฟลูออเรสเซนต์ อย่างมีนัยสำคัญทางสถิติที่ระดับ 0.05 (95% CI:Lower 182.218 Upper 245.331) th
dc.description.abstract The objective of the present study was to investigate the efficiency of light generated by T8 fluorescent lamps and LED lamps at Library and Information Center Building Huachiew Chalermprakiet University. The sample used in the study was the number of points in which the amounts of light were inspected. The total data of 194 points were collected on each of the floors. The tool used in the study was the Lux meter, which was calibrated and approved from the Thailand Institute of Seientific and Technological Research. The results of the present study were presented in numbers and percentages. Independent t-test was utilized to compare the amount of light between T8 fluorescent lamps and LED lamps. From the total of 194 points, it was found that only 27.84% of the points were above the passing standard when T8 fluorescent lamps were installed. The averagee light output generated by the fluorescent lamps was 380.21 Lux, which was below the minimum standard stated by the law. After the fluorescent lamps were replaced by LED lamps, 85.57% of the points passed the standard. The average light output generated by the LED lamps was 593.98 Lux. Using independent t-test, the results showed that the average light output generated by the LED lamps was significantly, higher that the fluorescent lamps (95% CI:Lower 182.218 Upper 245.331). th
dc.description.sponsorship ได้รับทุนอุดหนุนจากมหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติปีการศึกษา 2558 th
dc.language.iso th th
dc.publisher มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ th
dc.subject มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ. ศูนย์บรรณสารสนเทศ th
dc.subject Huachiew Chalermprakiet University. Library and Information Center th
dc.subject อาคาร -- การใช้พลังงาน th
dc.subject อาคาร -- แสงสว่าง th
dc.subject Buildings -- Lighting th
dc.subject Buildings -- Energy conservation th
dc.subject การส่องสว่างด้วยไฟฟ้า th
dc.subject Electric lighting th
dc.subject หลอดไฟฟ้า th
dc.subject Electric lamps th
dc.title การเปรียบเทียบความส่องสว่างของการใช้หลอดไฟฟลูออดรสเซนต์กับหลอด LED ในอาคารศูนย์บรรณสารสนเทศ มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ th
dc.title.alternative Comparison of the Illumination between the Fluorescent and the LEDLamps at Library and Information Center Building Huachiew Chalermprakiet University th
dc.type Technical Report th


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account