dc.contributor.author |
Weerapong Rukapan |
|
dc.contributor.author |
Benyapa Khananthai |
|
dc.contributor.author |
Thirdpong Srisukphun |
|
dc.contributor.author |
Wilai Chiemchaisri |
|
dc.contributor.author |
Chart Chiemchaisri |
|
dc.contributor.author |
วีระพงค์ รุกขพันธ์ |
|
dc.contributor.author |
เบญญาภา ขนันไทย |
|
dc.contributor.author |
เทอดพงศ์ ศรีสุขพันธุ์ |
|
dc.contributor.author |
วิไล เจียมไชยศรี |
|
dc.contributor.author |
ชาติ เจียมไชยศรี |
|
dc.contributor.other |
Kasetsart University. Faculty of Engineering |
th |
dc.contributor.other |
Kasetsart University. Faculty of Engineering |
th |
dc.contributor.other |
Huachiew Chalermprakiat University. Faculty of Public and Environmental Health |
th |
dc.contributor.other |
Kasetsart University. Faculty of Engineering |
th |
dc.contributor.other |
Kasetsart University. Faculty of Engineering |
th |
dc.date.accessioned |
2024-03-07T02:54:27Z |
|
dc.date.available |
2024-03-07T02:54:27Z |
|
dc.date.issued |
2015 |
|
dc.identifier.citation |
Water Sci Technol (2015) 71 (4): 580–587. |
th |
dc.identifier.other |
https://doi.org/10.2166/wst.2014.468 |
|
dc.identifier.uri |
https://has.hcu.ac.th/jspui/handle/123456789/1819 |
|
dc.description |
สามารถเข้าถึงบทความฉบับเต็มได้ที่
https://iwaponline.com/wst/article-abstract/71/4/580/28576/Comparison-of-reverse-osmosis-membrane-fouling?redirectedFrom=fulltext |
th |
dc.description.abstract |
Fouling characteristics of reverse osmosis (RO) membrane with chemical coagulation and microfiltration (MF) pre-treatment were investigated at full-scale leachate treatment systems. In chemical coagulation pre-treatment, solid separation from stabilized leachate was performed by ferric chloride coagulation followed by sand filtration. Meanwhile, MF pre-treatment and the RO system utilized direct filtration using a 0.03 µm membrane without chemical addition. MF pre-treatment yielded better pollutant removals in terms of organics and nitrogen. The study on effect of pre-treatment on RO membrane fouling revealed that accumulated foulant on the RO membrane in MF pre-treatment was significantly lower than that of chemical coagulation. Nevertheless, NaOH cleaning of the fouled RO membrane after chemical coagulation pre-treatment could better recover its permeate flux, thus suggesting that the formation of a loose-structure cake layer by chemical coagulation pre-treatment could allow effective penetration of chemical cleaning and detachment of foulant layer from the membrane surface. |
th |
dc.language.iso |
en_US |
th |
dc.subject |
เมมเบรน (ชีววิทยา) |
th |
dc.subject |
Membranes (Biology) |
th |
dc.subject |
การกรองระดับอนุภาค |
th |
dc.subject |
Microfiltration |
th |
dc.subject |
น้ำชะขยะ -- การบำบัด |
th |
dc.subject |
Leachate -- Purification |
th |
dc.title |
Comparison of reverse osmosis membrane fouling characteristics in full-scale leachate treatment systems with chemical coagulation and microfiltration pre-treatments |
th |
dc.type |
Article |
th |