DSpace Repository

Comparison of reverse osmosis membrane fouling characteristics in full-scale leachate treatment systems with chemical coagulation and microfiltration pre-treatments

Show simple item record

dc.contributor.author Weerapong Rukapan
dc.contributor.author Benyapa Khananthai
dc.contributor.author Thirdpong Srisukphun
dc.contributor.author Wilai Chiemchaisri
dc.contributor.author Chart Chiemchaisri
dc.contributor.author วีระพงค์ รุกขพันธ์
dc.contributor.author เบญญาภา ขนันไทย
dc.contributor.author เทอดพงศ์ ศรีสุขพันธุ์
dc.contributor.author วิไล เจียมไชยศรี
dc.contributor.author ชาติ เจียมไชยศรี
dc.contributor.other Kasetsart University. Faculty of Engineering th
dc.contributor.other Kasetsart University. Faculty of Engineering th
dc.contributor.other Huachiew Chalermprakiat University. Faculty of Public and Environmental Health th
dc.contributor.other Kasetsart University. Faculty of Engineering th
dc.contributor.other Kasetsart University. Faculty of Engineering th
dc.date.accessioned 2024-03-07T02:54:27Z
dc.date.available 2024-03-07T02:54:27Z
dc.date.issued 2015
dc.identifier.citation Water Sci Technol (2015) 71 (4): 580–587. th
dc.identifier.other https://doi.org/10.2166/wst.2014.468
dc.identifier.uri https://has.hcu.ac.th/jspui/handle/123456789/1819
dc.description สามารถเข้าถึงบทความฉบับเต็มได้ที่ https://iwaponline.com/wst/article-abstract/71/4/580/28576/Comparison-of-reverse-osmosis-membrane-fouling?redirectedFrom=fulltext th
dc.description.abstract Fouling characteristics of reverse osmosis (RO) membrane with chemical coagulation and microfiltration (MF) pre-treatment were investigated at full-scale leachate treatment systems. In chemical coagulation pre-treatment, solid separation from stabilized leachate was performed by ferric chloride coagulation followed by sand filtration. Meanwhile, MF pre-treatment and the RO system utilized direct filtration using a 0.03 µm membrane without chemical addition. MF pre-treatment yielded better pollutant removals in terms of organics and nitrogen. The study on effect of pre-treatment on RO membrane fouling revealed that accumulated foulant on the RO membrane in MF pre-treatment was significantly lower than that of chemical coagulation. Nevertheless, NaOH cleaning of the fouled RO membrane after chemical coagulation pre-treatment could better recover its permeate flux, thus suggesting that the formation of a loose-structure cake layer by chemical coagulation pre-treatment could allow effective penetration of chemical cleaning and detachment of foulant layer from the membrane surface. th
dc.language.iso en_US th
dc.subject เมมเบรน (ชีววิทยา) th
dc.subject Membranes (Biology) th
dc.subject การกรองระดับอนุภาค th
dc.subject Microfiltration th
dc.subject น้ำชะขยะ -- การบำบัด th
dc.subject Leachate -- Purification th
dc.title Comparison of reverse osmosis membrane fouling characteristics in full-scale leachate treatment systems with chemical coagulation and microfiltration pre-treatments th
dc.type Article th


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account