DSpace Repository

การพัฒนานวัตกรรมเครื่องสั่นสะเทือนปอดสำหรับผู้ป่วยเด็กที่มีปัญหาในการระบายเสมหะ

Show simple item record

dc.contributor.author ณฐมน สีธิแก้ว
dc.contributor.author พิชิตพล โชติกุลนันท์
dc.contributor.author จริยา ทรัพย์เรือง
dc.contributor.author Nathamon Seethikaew
dc.contributor.author Phichitphon Chotikunnan
dc.contributor.author Jariya Supruang
dc.contributor.other Maefahluang University. School of Nursing en
dc.contributor.other Rangsit University. College of Biomedical Engineering en
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Nursing en
dc.date.accessioned 2024-09-29T06:19:02Z
dc.date.available 2024-09-29T06:19:02Z
dc.date.issued 2022
dc.identifier.citation วารสารพยาบาลทหารบก 23, 2 (พฤษภาคม-สิงหาคม 2565) : 418-428. en
dc.identifier.uri https://has.hcu.ac.th/jspui/handle/123456789/2947
dc.description สามารถเข้าถึงบทความฉบับเต็ม (Full text) ได้ที่ : https://he01.tci-thaijo.org/index.php/JRTAN/article/view/250381/174830 en
dc.description.abstract การวิจัยเพื่อพัฒนานี้มีวัตถุประสงค์เพื่อพัฒนานวัตกรรมเครื่องสั่นสะเทือนปอดหรับผู้ป่สำวยเด็กที่มีปัญหาในการระบายเสมหะและศึกษาความพึงพอใจและประเมินประคุณภาพนวัตกรรม การดำเนินการ นวัตกรรมเครื่องสั่นสะเทือนปอดสำหรับผู้ป่วยเด็กที่มีปัญหาในการระบายเสมหะ ประกอบด้วย 2 ระยะ ระยะที่ 1 การพัฒนานวัตกรรมเครื่องสั่นสะเทือนปอดในการระบายเสมหะ สำหรับผู้ป่วยเด็กที่มีปัญหาในการระบายเสมหะ ระยะที่ 2 ศึกษาความพึงพอใจและประเมินคุณภาพนวัตกรรมของผู้ปกครองที่มี ต่อ:เครื่องสั่นสะเทือนปอดในการระบายเสมหะสำหรับผู้ป่วยเด็กที่มีปัญหาในการระบายเสมหะ กลุ่มตัวอย่างที่ใช้คือ ผู้ปกครองที่มี เด็กอายุ 2 - 5 ปี ณ ชุมชนตำบลป่าแงะ อำเภอพาน จ.เชียงราย และทดลองใช้นวัตกรรม จำนวน 30 คน โดยใช้แบบสอบถามของ ความพึงพอใจ (IOC = 0.79 และ α = .80) และประเมินประคุณภาพนวัตกรรม (IOC = 0.80 และ α = .80) วิเคราะห์ข้อมูลโดย ใช้สถิติเชิงบรรยาย ผลการดำเนินงานพบว่า 1) นวัตกรรมเครื่องสั่นสะเทือนปอดในการระบายเสมหะสำหรับผู้ป่วยเด็กที่มีปัญหาใน การระบายเสมหะภายในประกอบด้วย มอเตอร์และวงจรควบคุมการสั่น 2 ฟังก์ชัน คือ ฟังก์ชันการสั่นสะเทือนแบบต่อเนื่องและ ฟังก์ชันการสั่นสะเทือนแบบสั่นและหยุดเป็นช่วงเวลา พร้อมคู่มือการใช้นวัตกรรม และ 2) ระดับความพึงพอใจต่อการใช้นวัตกรรม อยู่ในระดับมากที่สุด ( = 3.54 - 3.80, SD = 0.50 - 0.70) และระดับการประเมินคุณภาพของนวัตกรรมอยู่ในระดับมากที่สุด ( = 3.65 - 3.75, SD = 0.60 - 0.70) นอกจากนี้แนวทางพัฒนานวัตกรรมต่อไป คือการนำผลการใช้นวัตกรรมเครื่องสั่นสะเทือน ปอดที่มีปัญหาในการระบายเสมหะไปใช้กับเด็กทีมีปัญหาการคั่งค้างของเสมหะในจำนวนที่มากขึ้น และเปรียบเทียบกับการระบาย เสมหะวิธีอื่น ๆ เพื่อการประเมินนวัตกรรมให้มีประสิทธิภาพต่อไป en
dc.description.abstract The purposes of this research were to develop an innovative vibrate for drainage secretion of pediatric patients and study satisfaction and quality assessment of the innovation. A process of an innovative vibrate for drainage secretion of pediatric patients consisted of two parts. The first one was the process of developing an innovative vibrate for drainage secretion of pediatric patients and The second one was study of satisfaction and quality assessment of the innovation among caregivers. Samples were 30 caregivers who had child 2-5 years at Pa Ngae community, Pa Ngae sub-district, Pa Daet district, Chiang Rai Province and welcome to use the innovation. They respond a questionnaire including satisfaction (IOC =0.79 and α = .80) and quality assessment of the innovation (IOC =0.80 and α = .80). Data analysis was descriptive statistics. The results showed 1) innovative vibrate for drainage secretion of pediatric patients and 2)means of satisfaction and of quality assessment of the innovation. The study showed the development of an innovative vibrate for drainage secretion of pediatric patients innovation included instruction and motor and control of vibration system. Means of satisfaction were much more ( = 3.54 - 3.80, SD = 0.50 - 0.70) and means of quality assessment of the innovation were also much more ( = 3.65 - 3.75, SD = 0.60 - 0.70). Therefore, the development of an innovative vibrate for drainage secretion of pediatric patients is appropriate for use. For future study, the development of an innovative vibrate for drainage secretion of pediatric patients should be used with more number of pediatric patients with secretion obstruction and compare with other innovative vibrators to assess the effectiveness. en
dc.language.iso th en
dc.subject เครื่องสั่นสะเทือนปอด en
dc.subject Chest vibrator en
dc.subject ทางเดินหายใจติดเชื้อในเด็ก en
dc.subject Respiratory infections in children en
dc.subject โรคทางเดินหายใจในเด็ก en
dc.subject Pediatric respiratory diseases en
dc.subject เสมหะ en
dc.subject Sputum en
dc.subject การระบายเสมหะ en
dc.subject Drainage secretion en
dc.title การพัฒนานวัตกรรมเครื่องสั่นสะเทือนปอดสำหรับผู้ป่วยเด็กที่มีปัญหาในการระบายเสมหะ en
dc.title.alternative Innovation Development Vibrate for Drainage Secretion of Pediatric Patients en
dc.type Article en


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account