DSpace Repository

Foulant interaction and RO productivity in textile wastewater reclamation plant

Show simple item record

dc.contributor.author Thirdpong Srisukphun
dc.contributor.author Chart Chiemchaisri
dc.contributor.author T. Urase
dc.contributor.author K. Yamamoto
dc.contributor.author เทอดพงศ์ ศรีสุขพันธุ์
dc.contributor.author ชาติ เจียมไชยศรี
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Public and Environmental Health en
dc.contributor.other Kasetsart University. Faculty of Engineering en
dc.contributor.other Tokyo University of Technology. School of Bioscience and Biotechnology en
dc.contributor.other The University of Tokyo. Environmental Science Center en
dc.date.accessioned 2024-10-28T13:00:19Z
dc.date.available 2024-10-28T13:00:19Z
dc.date.issued 2010
dc.identifier.citation Desalination 250, 2, (15 January 2010) : 845-849 en
dc.identifier.other https://doi.org/10.1016/j.desal.2008.11.054
dc.identifier.uri https://has.hcu.ac.th/jspui/handle/123456789/3165
dc.description สามารถเข้าถึงบทความฉบับเต็ม (Full text) ได้ที่ : https://www.sciencedirect.com/journal/desalination/vol/250/issue/2 en
dc.description.abstract Foulant interaction and productivity of reverse osmosis (RO) membrane during textile wastewater reclamation were studied. Synthetic textile wastewater composed of salt, surfactant and reactive dye was used in the experiment. RO productivity was assessed using cross-flow membrane filtration unit. The result revealed that surfactant was the major cause of membrane fouling. When the surfactant concentration maintains lower than the critical micelle concentration (CMC), RO productivity was influenced by the concentration of surfactant. Therefore, lowest productivity was observed when the surfactant concentration approached CMC. When the concentration level rose above CMC, the surfactant micelle was formed within the bulk solution and this subsequently yielded an increase in RO productivity. The formed micelle decreased the adsorption capacity of surfactant monomer. Moreover, the appearance of aggregation between surfactant and reactive dye lowered the fouling potential of the mixtures especially when compared to the wastewater containing only surfactant at a higher concentration than CMC. en
dc.language.iso en_US en
dc.subject Reverse osmosis en
dc.subject ออสโมซิสผันกลับ en
dc.subject Fouling en
dc.subject การเกิดตะกรัน en
dc.subject Textile Waste en
dc.subject ของเสียจากสิ่งทอ en
dc.subject Membranes (Technology) en
dc.subject เมมเบรน (เทคโนโลยี) en
dc.subject Sewage -- Recycling en
dc.subject น้ำเสีย – การนำกลับมาใช้ใหม่ en
dc.title Foulant interaction and RO productivity in textile wastewater reclamation plant en
dc.type Article en