Please use this identifier to cite or link to this item:
https://has.hcu.ac.th/jspui/handle/123456789/1249
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | ฐิตาภรณ์ เหลืองวิลัย | - |
dc.contributor.author | อุมารินทร์ พูลพานิชอุปถัมย์ | - |
dc.contributor.author | สุรวิทย์ นันตะพร | - |
dc.contributor.author | จิตรภณ โรจน์กิรติการ | - |
dc.contributor.author | Titaporn Luangwilai | - |
dc.contributor.author | Umarin Poolpanichuppatam | - |
dc.contributor.author | Surawit Nantaporn | - |
dc.contributor.author | Jittapon Rojkiratikarn | - |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Public and Environmental Health | th |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Public and Environmental Health | - |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Public and Environmental Health | - |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Public and Environmental Health | - |
dc.date.accessioned | 2023-03-12T15:35:01Z | - |
dc.date.available | 2023-03-12T15:35:01Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | https://has.hcu.ac.th/jspui/handle/123456789/1249 | - |
dc.description.abstract | การวิจัยครั้งนี้ มีวัตถุประสงค์เพื่อศึกษาประสิทธิภาพแสงสว่าง อาคารศูนย์บรรณสารสารสนเทศ มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ ระหว่างหลอดฟลูออเรสเซนต์ T8 และหลอด LED กลุ่มตัวอย่างที่ใช้ในการวิจัย คือ จำนวนจุดตรวจวัดความเข้มแสงสว่าง อาคารบรรณสารสนเทศ จำนวนทั้งหมด 194 จุด โดยเป็นการเก็บจากทั้งหมดทุกชั้้นของอาคารบรรณสาร เครื่องมือที่ใช้ในการวิจัยในครั้งนี้ คือ เครื่องตรวจวัดความเข้มแสงสว่าง ที่ผ่านการปรับเทียบความถูกต้องของเครื่องมือโดยศูนย์ทดสอบและมาตรวิทยา กระทรวงวิทยาศาสตร์และเทคโนโลยี มีการนำเสนอผลการศึกษาความเข้มแสงสว่างโดยแสดงเป็นจำนวน ร้อยละ และวิเคราะห์ข้อมูลการเปรียบเทียบความเข้มแสงสว่างระหว่างหลอดฟลูออเรสเซนต์ T8 และหลอด LED โดยใช้สถิติ Indenpendent t-test ผลการศึกษาจากกลุ่มตัวอย่างทั้งหมด 194 จุด พบว่า ประสิทธิภาพของแสงสว่างจากหลอดฟลูออเรสเซนต์ T8 มีจุดที่มีความเข้มแสงสว่างผ่านตามเกณฑ์มาตรฐานคิดเป็นร้อยละ 27.84 มีค่าความเข้มแสงสว่างอยู่ในเกณฑ์ต่ำกว่ามาตรฐานตามกฎหมายกำหนด มีค่าเฉลี่ยอยู่ที่ 380.21 Lux เมื่อเปลี่ยนเป็นหลอดไฟ LED มีจุดที่มีความเข้มแสงสว่างผ่านตามเกณฑ์มาตรฐานคิดเป็นร้อยละ 85.57 มีค่าความเข้มแสงสว่างอยู่ในเกณฑ์สูงผ่านค่ามาตรฐานตามกฎหมายกำหนด มีค่าเฉลี่ยอยู่ที่ 593.98 Lux และจากการทดสอบด้วย Independent t-test แสดงให้เห็นว่าค่าเฉลี่ยของความเข้มแสงสว่างจากหลอด LED สูงกว่าค่าเฉลี่ยของความเข้มแสงสว่างจากหลอดฟลูออเรสเซนต์ อย่างมีนัยสำคัญทางสถิติที่ระดับ 0.05 (95% CI:Lower 182.218 Upper 245.331) | th |
dc.description.abstract | The objective of the present study was to investigate the efficiency of light generated by T8 fluorescent lamps and LED lamps at Library and Information Center Building Huachiew Chalermprakiet University. The sample used in the study was the number of points in which the amounts of light were inspected. The total data of 194 points were collected on each of the floors. The tool used in the study was the Lux meter, which was calibrated and approved from the Thailand Institute of Seientific and Technological Research. The results of the present study were presented in numbers and percentages. Independent t-test was utilized to compare the amount of light between T8 fluorescent lamps and LED lamps. From the total of 194 points, it was found that only 27.84% of the points were above the passing standard when T8 fluorescent lamps were installed. The averagee light output generated by the fluorescent lamps was 380.21 Lux, which was below the minimum standard stated by the law. After the fluorescent lamps were replaced by LED lamps, 85.57% of the points passed the standard. The average light output generated by the LED lamps was 593.98 Lux. Using independent t-test, the results showed that the average light output generated by the LED lamps was significantly, higher that the fluorescent lamps (95% CI:Lower 182.218 Upper 245.331). | th |
dc.description.sponsorship | ได้รับทุนอุดหนุนจากมหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติปีการศึกษา 2558 | th |
dc.language.iso | th | th |
dc.publisher | มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ | th |
dc.subject | มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ. ศูนย์บรรณสารสนเทศ | th |
dc.subject | Huachiew Chalermprakiet University. Library and Information Center | th |
dc.subject | อาคาร -- การใช้พลังงาน | th |
dc.subject | อาคาร -- แสงสว่าง | th |
dc.subject | Buildings -- Lighting | th |
dc.subject | Buildings -- Energy conservation | th |
dc.subject | การส่องสว่างด้วยไฟฟ้า | th |
dc.subject | Electric lighting | th |
dc.subject | หลอดไฟฟ้า | th |
dc.subject | Electric lamps | th |
dc.title | การเปรียบเทียบความส่องสว่างของการใช้หลอดไฟฟลูออดรสเซนต์กับหลอด LED ในอาคารศูนย์บรรณสารสนเทศ มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ | th |
dc.title.alternative | Comparison of the Illumination between the Fluorescent and the LEDLamps at Library and Information Center Building Huachiew Chalermprakiet University | th |
dc.type | Technical Report | th |