Please use this identifier to cite or link to this item:
https://has.hcu.ac.th/jspui/handle/123456789/2338
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chompunoot Sinthupibulyakit | - |
dc.contributor.author | Tiparat Potipitak | - |
dc.contributor.author | ชมพูนุท สินธุพิบูลยกิจ | - |
dc.contributor.author | ทิพย์รัตน์โพธิพิทักษ์ | - |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Medical Technology | en |
dc.contributor.other | Reginal Medical Sciences Center 5 | en |
dc.date.accessioned | 2024-05-27T13:20:01Z | - |
dc.date.available | 2024-05-27T13:20:01Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | https://has.hcu.ac.th/jspui/handle/123456789/2338 | - |
dc.description | Proceedings of the 6th National and International Conference on "Research to Serve Society", 22nd June 2018 at Huachiew Chalermprakiet University, Bangphli District, Samutprakarn, Thailand. p. 170-177. | en |
dc.description.abstract | Patients with hemoglobin (Hb) variants may produce false hemoglobin A1c (HbA1c) measurement leading to misdiagnosis or mistreatment. This study aimed to evaluate the effects of Hb E on five different HbA1c analytical principles. HbA1c levels of 160 EDTA blood samples including Hb type A2A (N=51), heterozygous Hb E (N=104), and homozygous Hb E (N=5) were analyzed by immunoturbidimetric method, HPLC, LPLC, enzymatic assay, and boronate affinity chromatography. The strong positive correlations of HbA1c levels measured by all assays were observed (r=0.797 to 0.962, p<0.001). The HbA1c results analyzed by immunoassay and enzymatic assay were significant higher than boronate affinity chromatography (p<0.05), in Hb type A2A and heterozygous Hb E samples. However, these differenced between assays in each hemoglobin typing were comparable. The results by using HPLC were under reportable range in homozygous Hb E group. The mean differences between HbA1c results analyzed by using LPLC and other 4 testes methods were significantly higher in heterozygous Hb E samples with Hb F>2%, compared to samples with Hb F <=2% (p<0.05). This work showed a good comparability of HbA1c assays, although, some methods were influenced by high levels of Hb E and Hb F. Therefore, Hb E and Hb F are interfering factors that laboratories must be aware when reporting results if its presence is suspected. | en |
dc.language.iso | en_US | en |
dc.rights | มหาวิทยาลัยหัวเฉียวเฉลิมพระเกียรติ | en |
dc.subject | ฮีโมโกลบินเอวันซี | en |
dc.subject | Hemoglobin A1c protein, human | en |
dc.subject | ฮีโมโกลบินอี | en |
dc.subject | Hemoglobin E | en |
dc.subject | ไฮเปอร์ฟอร์แมนซ์ลิควิดโครมาโตกราฟี | en |
dc.subject | High performance liquid chromatography | en |
dc.subject | ลิควิดโครมาโตกราฟี | en |
dc.subject | Liquid chromatography | en |
dc.title | Effect of Hemoglobin E on Measurement of Hemoglobin A1c by Fire Different Methods | en |
dc.type | Proceeding Document | en |
Appears in Collections: | Medical Technology - Proceeding Document |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
HCU2018-Effect-of-Hemoglobin-E.pdf | 276.41 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.