Please use this identifier to cite or link to this item:
https://has.hcu.ac.th/jspui/handle/123456789/3588
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Neramitr Chirakanphaisarn | - |
dc.contributor.author | Thadsanee Thongkanluang | - |
dc.contributor.author | Yuwathida Chiwpreechar | - |
dc.contributor.author | เนรมิธ จิรกาญจน์ไพศาล | - |
dc.contributor.author | ทัศนีย์ ทองก้านเหลือง | - |
dc.contributor.author | ยุวธิดา ชิวปรีชา | - |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Science and Technology | en |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Science and Technology | en |
dc.contributor.other | Huachiew Chalermprakiet University. Faculty of Science and Technology | en |
dc.date.accessioned | 2025-01-29T02:40:15Z | - |
dc.date.available | 2025-01-29T02:40:15Z | - |
dc.date.issued | 2016 | - |
dc.identifier.uri | https://has.hcu.ac.th/jspui/handle/123456789/3588 | - |
dc.description | 2016 Sixth International Conference on Digital Information Processing and Communications (ICDIPC), 21-23 April 2016 at Beirut, Lebanon pp. 70-74, DOI: 10.1109/ICDIPC.2016.7470794 | en |
dc.description | สามารถเข้าถึงบทความฉบับเต็มได้ที่ : https://ieeexplore.ieee.org/document/7470794 | en |
dc.description.abstract | The preliminary research constructs the heart beat or pulse measurement for medical science. The electrical pulse signal analysis that supports one significant clinical study. The research prototype focuses the pulse rate and analysis system which consist of hardware and software parts. The hardware uses the ATMEGA 2560 ADK R3 for processing the input optical sensors, output result to LCD, and record data into SD memory card. The software as embedded algorithm is designed for controlling the input/output parts. Research techniques are applied in term of analog to digital converter, I2C, and data grouping. The 40 subjects are informed consent and measured with ethical research. Experimental result explains the subject behaviors with maximum/minimum pulse values, patterns, and similarity three groups. The distinctive point of medical and health science prototype is accuracy, durability, low power consumption, and cheaper price. | en |
dc.language.iso | en_US | en |
dc.rights | IEEE | en |
dc.subject | Heart beat | en |
dc.subject | อัตราการเต้นของหัวใจ | en |
dc.subject | Pulse – Measurement | en |
dc.subject | ชีพจร -- การวัด | en |
dc.subject | Optical sensor | en |
dc.title | Heart rate measurement and electrical pulse signal analysis for subjects span of 20–80 years | en |
dc.type | Proceeding Document | en |
Appears in Collections: | Science and Technology - Proceeding Document |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Heart-rate-measurement-and-electrical-pulse-signal-analysis.pdf | 66.14 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.