Please use this identifier to cite or link to this item: https://has.hcu.ac.th/jspui/handle/123456789/3588
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNeramitr Chirakanphaisarn-
dc.contributor.authorThadsanee Thongkanluang-
dc.contributor.authorYuwathida Chiwpreechar-
dc.contributor.authorเนรมิธ จิรกาญจน์ไพศาล-
dc.contributor.authorทัศนีย์ ทองก้านเหลือง-
dc.contributor.authorยุวธิดา ชิวปรีชา-
dc.contributor.otherHuachiew Chalermprakiet University. Faculty of Science and Technologyen
dc.contributor.otherHuachiew Chalermprakiet University. Faculty of Science and Technologyen
dc.contributor.otherHuachiew Chalermprakiet University. Faculty of Science and Technologyen
dc.date.accessioned2025-01-29T02:40:15Z-
dc.date.available2025-01-29T02:40:15Z-
dc.date.issued2016-
dc.identifier.urihttps://has.hcu.ac.th/jspui/handle/123456789/3588-
dc.description2016 Sixth International Conference on Digital Information Processing and Communications (ICDIPC), 21-23 April 2016 at Beirut, Lebanon pp. 70-74, DOI: 10.1109/ICDIPC.2016.7470794en
dc.descriptionสามารถเข้าถึงบทความฉบับเต็มได้ที่ : https://ieeexplore.ieee.org/document/7470794en
dc.description.abstractThe preliminary research constructs the heart beat or pulse measurement for medical science. The electrical pulse signal analysis that supports one significant clinical study. The research prototype focuses the pulse rate and analysis system which consist of hardware and software parts. The hardware uses the ATMEGA 2560 ADK R3 for processing the input optical sensors, output result to LCD, and record data into SD memory card. The software as embedded algorithm is designed for controlling the input/output parts. Research techniques are applied in term of analog to digital converter, I2C, and data grouping. The 40 subjects are informed consent and measured with ethical research. Experimental result explains the subject behaviors with maximum/minimum pulse values, patterns, and similarity three groups. The distinctive point of medical and health science prototype is accuracy, durability, low power consumption, and cheaper price.en
dc.language.isoen_USen
dc.rightsIEEEen
dc.subjectHeart beaten
dc.subjectอัตราการเต้นของหัวใจen
dc.subjectPulse – Measurementen
dc.subjectชีพจร -- การวัดen
dc.subjectOptical sensoren
dc.titleHeart rate measurement and electrical pulse signal analysis for subjects span of 20–80 yearsen
dc.typeProceeding Documenten
Appears in Collections:Science and Technology - Proceeding Document

Files in This Item:
File Description SizeFormat 
Heart-rate-measurement-and-electrical-pulse-signal-analysis.pdf66.14 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.