DSpace Repository

Heart rate measurement and electrical pulse signal analysis for subjects span of 20–80 years

Show simple item record

dc.contributor.author Neramitr Chirakanphaisarn
dc.contributor.author Thadsanee Thongkanluang
dc.contributor.author Yuwathida Chiwpreechar
dc.contributor.author เนรมิธ จิรกาญจน์ไพศาล
dc.contributor.author ทัศนีย์ ทองก้านเหลือง
dc.contributor.author ยุวธิดา ชิวปรีชา
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Science and Technology en
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Science and Technology en
dc.contributor.other Huachiew Chalermprakiet University. Faculty of Science and Technology en
dc.date.accessioned 2025-01-29T02:40:15Z
dc.date.available 2025-01-29T02:40:15Z
dc.date.issued 2016
dc.identifier.uri https://has.hcu.ac.th/jspui/handle/123456789/3588
dc.description 2016 Sixth International Conference on Digital Information Processing and Communications (ICDIPC), 21-23 April 2016 at Beirut, Lebanon pp. 70-74, DOI: 10.1109/ICDIPC.2016.7470794 en
dc.description สามารถเข้าถึงบทความฉบับเต็มได้ที่ : https://ieeexplore.ieee.org/document/7470794 en
dc.description.abstract The preliminary research constructs the heart beat or pulse measurement for medical science. The electrical pulse signal analysis that supports one significant clinical study. The research prototype focuses the pulse rate and analysis system which consist of hardware and software parts. The hardware uses the ATMEGA 2560 ADK R3 for processing the input optical sensors, output result to LCD, and record data into SD memory card. The software as embedded algorithm is designed for controlling the input/output parts. Research techniques are applied in term of analog to digital converter, I2C, and data grouping. The 40 subjects are informed consent and measured with ethical research. Experimental result explains the subject behaviors with maximum/minimum pulse values, patterns, and similarity three groups. The distinctive point of medical and health science prototype is accuracy, durability, low power consumption, and cheaper price. en
dc.language.iso en_US en
dc.rights IEEE en
dc.subject Heart beat en
dc.subject อัตราการเต้นของหัวใจ en
dc.subject Pulse – Measurement en
dc.subject ชีพจร -- การวัด en
dc.subject Optical sensor en
dc.title Heart rate measurement and electrical pulse signal analysis for subjects span of 20–80 years en
dc.type Proceeding Document en


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account